ACOM 2000A specification
   
 
   
   
  • RF output: 1500-2000 W keyed carrier or SSB - no time limit. Constant carrier modes 1500W RF output - no time limit with auxiliary cooling fan.
•
Frequency coverage: All amateur bands 1.8-24.5 MHz. 28 Mhz only with modification by licensed amateurs.
• Bandchange / Tuneup: Initial output matching process in less than 3 secs (typically 0.5 secs). Preset matching process / bandchange takes less than 0.2 second to move to different segment, same band and less than 1 sec for QSY to different band.
•
Tuning memories: Non-volatile for up to 10 antennas per frequency segment.
•
Drive power: Typically 50W for 1500W output.
• Input impedance: 50 ohms nominal. VSWR <1.5:1.
• Output tolerance: Up to 3:1 VSWR (2:1 on 160m) at full rated output before SWR protection circuit actuates. Higher SWR's tolerated at lower output.
• Harmonics: At least 50 dB below peak output at 1500W.
•
Intermodulation: At least 35 dB below peak output at 1500W.
•
T/R and keying: Vacuum Relay: QSK capable.
• Tubes and circuit: 4CX800A/GU74b tetrodes (2); resistive grid, PI-L output with RF negative feedback. Regulated screen grid voltage.
• ALC: Negative going, grid derived, -11v max, rear panel adjustable.
• Metering: Comprehensive.  Remote Control Unit provides flexible monitoring of all amplifier operating parameters.
•
Protection: Grid and screen current limiting, power inrush (soft-start provided), trip to excessive reflected power, RF arcs, password access protection if needed, correct T/R sequencing, tube exhaust overheat, cover interlock and HV crowbar.
•
Fault diagnosis: Remote Control Unit display and LED's plus "INFO Box" for 12 most recent events. PC interface (RS-232), plus remote phone line interrogation feature.
•
Cooling: Full cabinet forced-air. Rubber isolated blower.
• Transformer: 3.5 kVA with strip-wound Unisil-Hâ core.
•
AC power requirements: 100/120/200/220/240 VAC nominal. 50-60 Hz. 3500VA single phase at full power.
•
Physical: RF Unit: 17-1/4"W X 7"H X 17-3/4"D
   -(440W x 180H x 450D mm).
   -RCU: 5-1/4"W X 6-3/4"D X 1" H
   -(135 X 25H X 170D mm).
   -Shipped in two cartons total weight 80lb (36kg.) Plug in transformer for ease of installation and transport.
   -No controls on RF unit except ON/OFF. RF unit may be located up to 3 metres (10m with optional kit) from RCU.
   
 
   
 
ACOM International, Inc , 1988-2012 , All rights reserved